Ice machines combine a refrigeration circuit with a water circuit, and most faults live in the water side: scale on the evaporator, a clogged filter, a dirty water tray or a drain that cannot keep up. The result is low output, cloudy ice or a machine that cycles but never fills the bin.
We clean and descale the water circuit, check water quality and filtration, verify the refrigeration side, and test the harvest cycle. Where the machine is in a hot, greasy or dusty position, we also look at airflow and condenser condition.
What the work covers
- No ice, low output or slow production
- Cloudy, soft or oddly shaped ice
- Scale and slime build-up in the water circuit
- Water leaks and drain problems
- Condenser cleaning and fan faults
- Harvest cycle, sensor and control faults
When it is worth calling
- The bin empties faster than the machine can refill
- Ice that looks cloudy, wet or fused together
- Water on the floor or a constantly running inlet
- Grinding, buzzing or repeated cycling
- A machine that has not been descaled in a year
Coastal note
Cape Town's water and coastal air both leave their mark on ice machines. Scale insulates the evaporator, and salt-laden dust blocks condensers, so descaling and condenser cleaning belong on a schedule.